Richmond water heater pilot light won - I have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …

 
New Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ... . Resident of oklahomapercent27s second largest city

The Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need. I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and …I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit.For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long life richmond tankless gas hot water heater won't run. under the panel the red light was blinking 6 times. But now it is blinking constantly. Before it stopped working, the exhaust vent was clogged with sn …Oct 12, 2019 · Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to try Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... Some gas water heaters are equipped with a pilot light to light the main gas burner. The pilot must burn non-stop for a water heater to operate correctly. It should burn with a stable blue /yellow flame. If the pilot line or orifice gets clogged, the flame becomes smaller, burning the yellow/red flame. The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points. Slightly depress the gas control knob and turn clockwise to OFF position. Wait 5 minutes to clear out any gas. Stop and follow the safety precautions as above if you smell any gas. Go to the next step if you do not smell gas. Remove the outer door from the water heater. Do not attempt to remove the inner door.Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.07. Blocked Air Intake End-Note Richmond Water Heater Pilot Light Won’t Stay Lit [7 Easy Solutions] Your Richmond Water Heater pilot light won’t stay lit due to several reasons. These include a bad thermocouple, a tripped limit switch, plugged flammable vapor sensor, and a faulty gas valve.Press and hold down the button. Listen for the click and ignition. Your igniter should light the gas directly if it is a hot surface ignition. You will know it is working if you feel the heat coming from the unit. Lighting an intermittent pilot ignition: Locate the igniter button and knob.Step #3: While holding the knob, press the piezo igniter button at the same time. Keep pressing both buttons until the status light starts blinking. Step #4: Take a look at the viewport to see if the pilot light comes on. If yes, release the valve and set the knob to your desired temperature setting.1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and …Oct 12, 2019 · Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to try Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … read moreHere is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ...Turn the gas off on the main shutoff valve that is supplying a water heater. Remove the cover plate at the bottom of the water heater, if possible. Locate the pilot tube connected to the gas valve with the nut and disconnect it. There is also a thermocouple attached. If needed, disconnect it too.By Vikram May 7, 2023 If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won’t stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them.Jul 29, 2023 · Richmond Water Heater Pilot Light Won’t Stay Lit: A Detailed Discussion. As you can see from the table above, there are many reasons why the heater’s pilot light tends not to stay lit. And there are solutions for each problem. In the following part, I have discussed the issues in more detail and also shared how you can solve them. 1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.my water heater won't stay onI have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …Last night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...Mar 1, 2020 · The Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve. May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions … read moreReplace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.Mar 1, 2020 · The Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve. Sep 3, 2018 · I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote. Richmond water heater pilot light. Water heater thermocouple. How to bypass thermocouple. Richmond water heater pilot won't stay lit. Water heater pilot ligh...The Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve.07. Blocked Air Intake End-Note Richmond Water Heater Pilot Light Won’t Stay Lit [7 Easy Solutions] Your Richmond Water Heater pilot light won’t stay lit due to several reasons. These include a bad thermocouple, a tripped limit switch, plugged flammable vapor sensor, and a faulty gas valve.Jan 26, 2022 · Are you running out of hot water or your hot water is only lukewarm? The most common problem which can be easily fixed is your pilot light went out if you h... I used this to repair my 40Gal Richmond LP water heater model 6G40-32PF1. The replacement gasket and mounting seal are superior that the one that came with the heater itself. The line lengths provided were more than enough to remount on my water heater.Last night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...Nov 18, 2022 · The pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line. 1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.Richmond water heaters have a warranty that is specific to your water heater. The warranty varies based on the model. Some models, like the Marathon, have lifetime warranties, while others have a 6- or even a 12-year warranty.Sep 23, 2020 · Head down to the water heater to check the pilot and relight it. But first, learn the basics here. By Glenda Taylor and Bob Vila | Updated Sep 23, 2020 9:57 AM The pilot light is an important part of your Rheem water heater, but it might occasionally not light. Usually, relighting the light will restore your water heater’s functionality, but if the light won’t light, there’s a larger issue to address. Contents show 1 1. You Have a Blocked Gas Line 1.1 How To Fix 2 … Rheem Water Heater Pilot Light Won’t Light – Fixed Read More »Mar 1, 2020 · The Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve. 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective.Step #3: While holding the knob, press the piezo igniter button at the same time. Keep pressing both buttons until the status light starts blinking. Step #4: Take a look at the viewport to see if the pilot light comes on. If yes, release the valve and set the knob to your desired temperature setting.my water heater won't stay onIt is able to detect flammable vapors, protecting the water heater from excessive electricity flow and damage. In case the water heater pilot light doesn’t stay lit, it is possible that the thermal switch is either damaged or tripped. 3. Faulty thermocouple. Even if you’ve replaced the thermocouple, it is still possible that the ...Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.Richmond water heaters have a warranty that is specific to your water heater. The warranty varies based on the model. Some models, like the Marathon, have lifetime warranties, while others have a 6- or even a 12-year warranty.A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f...Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's lit01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ...Jan 5, 2006 · Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out. Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup the …May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. Press and hold down the button. Listen for the click and ignition. Your igniter should light the gas directly if it is a hot surface ignition. You will know it is working if you feel the heat coming from the unit. Lighting an intermittent pilot ignition: Locate the igniter button and knob.Head down to the water heater to check the pilot and relight it. But first, learn the basics here. By Glenda Taylor and Bob Vila | Updated Sep 23, 2020 9:57 AMUsually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's litUsually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.Step 03 – Drain The Tank. Before taking off the gas valve, you need to drain the water heater. Otherwise, you’ll end up with a mess on your hands. The hot water can also cause scalding. Turn off the cold water shutoff valve if you can locate it or shut off the water supply to your entire house.New Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ... Dec 31, 2015 · 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective. Oct 19, 2013 · I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v... It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read moreSep 25, 2021 · Have you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ... It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve).Feb 14, 2019 · A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f... I have a Richmond rmtgl74pvn tankless water heater that has worked great for5 years but it stopped working just now. Won't light, looks like there is no power to the board but I've checked that. read moreInstall a New Thermocouple. Insert the new thermocouple from the outside through the grommet or opening in the burner assembly manifold cover. Insert the thermocouple into its mounting bracket until it is fully seated or clicks into place. Position the thermocouple tip so that the pilot flame will envelop the top 3/8 to 1/2 inch of the ...The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article.Turn the gas off on the main shutoff valve that is supplying a water heater. Remove the cover plate at the bottom of the water heater, if possible. Locate the pilot tube connected to the gas valve with the nut and disconnect it. There is also a thermocouple attached. If needed, disconnect it too.It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c...

hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty.. The 12 best portable toilet for boat reviews for 2021

richmond water heater pilot light won

I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit.Clean those first before doing anything else. It's routine maintenance that needs to be done in any case. You need to remove the pilot burner, take the pilot tubing off and remove the pilot orifice. Sometimes you can clean the pilot orifice with the wire from a wire brush. Use a wire brush to clean the pilot burner.The pilot light is an important part of your Rheem water heater, but it might occasionally not light. Usually, relighting the light will restore your water heater’s functionality, but if the light won’t light, there’s a larger issue to address. Contents show 1 1. You Have a Blocked Gas Line 1.1 How To Fix 2 … Rheem Water Heater Pilot Light Won’t Light – Fixed Read More »Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Step #3: While holding the knob, press the piezo igniter button at the same time. Keep pressing both buttons until the status light starts blinking. Step #4: Take a look at the viewport to see if the pilot light comes on. If yes, release the valve and set the knob to your desired temperature setting.It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c...Dec 8, 2016 · I have a Richmond rmtgl74pvn tankless water heater that has worked great for5 years but it stopped working just now. Won't light, looks like there is no power to the board but I've checked that. read more If your pilot light on your Richmond water heater won’t stay lit, it’s usually due to a faulty thermocouple or a lack of combustible air. A problem with the thermocouple is significantly more common, but both could be causing problems. Today, we’ll examine why your water heater pilot light keeps going out and discuss ways you can fix it. For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long life 1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.6. Below is a picture of the lighting instructions for your water heater taken from Rheem's website. Make sure to follow the lighting instructions carefully and do not skip any steps. This same instruction set should be available as a sticker on your unit. It looks like you do in fact have to depress the knob in order to turn it so avoid using ...Apr 24, 2011 · I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit. The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article.If your pilot light on your Richmond water heater won’t stay lit, it’s usually due to a faulty thermocouple or a lack of combustible air. A problem with the thermocouple is significantly more common, but both could be causing problems. Today, we’ll examine why your water heater pilot light keeps going out and discuss ways you can fix it. Oct 12, 2019 · Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to try Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter - Answered by a verified HVAC TechnicianThe Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve.You can easily determine whether the gas valve of Richmond Water Heater gets bad or not by lighting the pilot and testing the thermocouple. Let’s start with lighting the pilot. Follow the manual and attempt to light the pilot. Press the pilot knob all the way down and keep pressing the igniter button. If the pilot light doesn’t come on ....

Popular Topics