Common array manager software - Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another might require special procedures.

 
The array management software configures both physical and logical storage components. The components of a storage array configuration are as follows. Initiator - A port on a Fibre Channel (FC) host bus adapter (HBA) that allows a host to gain access to the storage array. The initiator has a World Wide Name (WWN) that is globally unique.. Quatvn

The "Services" application can be launched in Windows to confirm that the service name "Sun_STK_FMS" (Sun Storage Common Array Manager Fault Management Service) is not running. See the example below: Additionally, the following errors may exist in the file C:\Program Files (x86)\Sun\Common Array …The Sun StorageTek Common Array Manager Installation Software CD provides three installation-related wizards: GUI software installer - Enables you to use a graphical user …The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …2 Sun StorageTek Common Array Manager Software 6.4.1 Release Notes • August 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes the following: Browser interface Local command …To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software. This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for documentation links. 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system.Download Sun Common Array Manager - best software for Windows. Sun Storage Common Array Manager Online Help: One Interface, Run-Anywhere Flexibility...Software Release Notes, Release 6.10 Update for Solaris OS Hosts September 2015 Review important late-breaking information about Sun Storage Common Array Manager 6.10 Update.Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …Free common array manager download. Development Tools downloads - Sun Storage Common Array Manager Online Help by Oracle Corporation and many more … The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation Options2 Sun StorageTek Common Array Manager Software 6.4.1 Release Notes • August 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes the following: Browser interface Local command …About Array Registration. When you install the management software on a new host, the Storage System Summary page displays as blank with no arrays listed. On all subsequent logins to the Common Array Manager, the Storage System Summary page is displayed with the arrays you registered with the software.The Sun StorageTek Common Array Manager software (5.1.3 and above) provides an easy-to-use interface from which you configure, manage, and monitor Sun StorageTek storage systems, including the Sun StorageTek 2500 Series Array. You can also use the Common Array Manager software to diagnose problems, view events, and monitor the …These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system …Service Advisor integrated with the Sun StorageTek Common Array Manager software. Reference information for the CLI Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in thisWindows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet … 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Sun Storage Common Array Manager Software Release ... - Oracle. EN. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk ...The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0 (English) l This document describes how to configure and monitor Oracle's Sun Storage, …How to Download Common Array Manager (CAM) Software and Patches [ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。. Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are also ... Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system.This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for documentation links.Start a DHCP server on the same subnet, then reboot the 2500 Series Array. Using the serial port interface (see Using the Serial Port Interface to Assign IP Addresses). Using the Sun StorageTek Common Array Manager (see the Sun StorageTek Common Array Manager Software Installation Guide). Configuring Static IP Addressing 2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... CAM is a software application that allows you to manage SAS-NEMs. and disk blades in a chassis from one central point. It is written. in Java so you can run it on any platform. …Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports. 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 5.1.3: Sun Connection (Auto Service Request): registration, telemetry, and automated case generation. Support for 2500 Series Arrays.This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Notas de la versión del software Sun Storage Common Array Manager, versión 6.10 l Revise la información más reciente e importante sobre la actualización 6.10 de Sun Storage Common Array Manager. Download : Sun Storage Common Array Manager, Software Release Notes, Release 6.10 Update for Solaris OS Hosts (English) l Review …About Array Registration. When you install the management software on a new host, the Storage System Summary page displays as blank with no arrays listed. On all subsequent logins to the Common Array Manager, the Storage System Summary page is displayed with the arrays you registered with the software.The Sun Storage Common Array Manager Installation and Setup Guide describes how to install Oracle’s Sun Storage Common Array Manager software and how to perform initial configuration for RAID and JBOD open systems storage arrays. For help with installing the arrays, see the hardware installation guide for your array.Dec 31, 2014 · Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit Count ... The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …The Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. The software includes a distributed architecture which enables you to manage Sun/StorageTek Storage platforms throughout your company, regardless of location.Note - For other arrays managed by the Sun StorageTek Common Array Manager, firmware, this release may require special firmware instructions. Refer to the Sun StorageTek Common Array Manager Software Release Notes, Release 6.1.2 (or later) for the latest firmware information and a list of firmware files for your array.SANtricity Storage Manager. SANtricity ES Storage Manager 10.77 Software and Array Documentation l. SANtricity Storage Manager 8.3x l. Sun Storage Common Array Manager Software. Sun Storage Common Array Manager 6.10 l. Sun Storage Common Array Manager 6.9 l.Notas de la versión del software Sun Storage Common Array Manager, versión 6.10 l Revise la información más reciente e importante sobre la actualización 6.10 de Sun Storage Common Array Manager. Download : Sun Storage Common Array Manager, Software Release Notes, Release 6.10 Update for Solaris OS Hosts (English) l Review …Goal. This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …List the management software application that<br /> you are logged in to.<br /> Modify the management software application<br /> that you are logged into.<br /> Show all of the operating systems that are<br /> supported by the array. The values returned can<br /> be used in subsequent requests to create or<br /> Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... “Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release NotesSee the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS. The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported. The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage systems, including the Sun StorageTek 6140 Array. You can also use the Common Array Manager software to diagnose problems, view events, and monitor the health of your array. The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported. Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. The Common Array Manager software can manage arrays with either in-band and out-of-band connections at the same time. Copying Configuration Files and In-Band Management. If you are going to copy a configuration file to a management host that will have in-band communication with the array, ...Software; User manual. Sun Storage Common Array Manager Array Administration Guide C H A P T E R. 1. ... “Logging Out of the Management Software” on page 10. About the Browser Interface. The browser interface provides …See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS. Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are also ... This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: ... User names in the array management software must be currently defined users on the host. To add new users to hosts running Solaris or Linux …Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another might require special procedures.Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using the Sun Storage Common Array Manager software, version 6.9.0.CAM is a software application that allows you to manage SAS-NEMs. and disk blades in a chassis from one central point. It is written. in Java so you can run it on any platform. …The purpose of this document is to provide an easily accessible reference for the supported browsers and operating systems for Sun Storage Common Array Manager (CAM), version 6.10. Scope Please refer to the page for Sun Storage Common Array Manager Software 6.10 Documentation on the Oracle Technology Network for complete information … Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options are also provided. Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using the Sun Storage Common Array Manager software, version 6.9.0.Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version … 2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and Service Advisor integrated with the Sun StorageTek Common Array Manager software. Reference information for the CLI Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in thisThe array management software configures both physical and logical storage components. The components of a storage array configuration are as follows. Initiator - A port on a Fibre Channel (FC) host bus adapter (HBA) that allows a host to gain access to the storage array. The initiator has a World Wide Name (WWN) that is globally unique.https://cam-management-host:6789. cam-management-host is the IP address or host name of the host where you installed the Common Array Manager software. 3. Log in as root (Solaris) or administrator (Windows). For Solaris OS and Linux, root already exists for the machine on which you installed the software.List the management software application that<br /> you are logged in to.<br /> Modify the management software application<br /> that you are logged into.<br /> Show all of the operating systems that are<br /> supported by the array. The values returned can<br /> be used in subsequent requests to create or<br /> File Name: am360a05.exe. File Size: 39.02 MB. Format Description: This file format consists of an archive of files that may be decompressed to a directory on the hard drive. The installation can then be done from that directory. Download. To ensure the integrity of your download, please verify the checksum value. Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. The Common Array Manager software can manage arrays with either in-band and out-of-band connections at the same time. Copying Configuration Files and In-Band Management. If you are going to copy a configuration file to a management host that will have in-band communication with the array, ...Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.For instructions to download CAM, please refer to <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches. For …4. Select Typical (full) to install the full Sun Storage Common Array Manager software. A full install includes the following packages: Management host software with GUI Data host proxy agent Administrator host CLI client 5. When the installation completes, the View Results screen is displayed. Install the Data Host Proxy Agent for JBOD Arrays

The Sun Storage Common Array Manager Installation and Setup Guide describes how to install Oracle’s Sun Storage Common Array Manager software and how to perform initial configuration for RAID and JBOD open systems storage arrays. For help with installing the arrays, see the hardware installation guide for your array.. Lax to msp

common array manager software

Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. ... Instead, you use the management software provided with the Unified Storage System. Please refer to J4200/J4400 Array System Overview. Solution. …Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation OptionsSun Storage Common Array Manager (CAM) - Version 6.0 and later: Sun StorageTek[TM] Flexline 380 (FLX380) with Common Array Manager ... reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware and management software compatibility. For instructions to download CAM, ...Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: ... [TM] Configuration Service or CAM Software., or SANtricity ES Storage Manager Solution Steps to Follow Every volume built on an Sun StorageTek [TM] 6000/25x0 array line has two properties, ...Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle’s Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0_20 product release.See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS.Sun StorageTek Array Administration Guide For Sun StorageTek Common Array Manager, Release 6.2: PDF: Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family: HTML: PDF: Sun StorageTek Common Array Manager User …The Common Array Manager software can manage arrays with either in-band and out-of-band connections at the same time. Copying Configuration Files and In-Band Management. If you are going to copy a configuration file to a management host that will have in-band communication with the array, ...Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system.Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …Sun StorageTek Common Array Manager contains two user interfaces, a full command line and a web UI. The web UI has not been evaluated for accessibility and is not included in this VPAT. ... Software shall not use flashing or blinking text, objects, or other elements having a flash or blink frequency greater than 2 Hz and lower than 55 Hz. … The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. 2 Sun StorageTek Common Array Manager Software 6.5.0 Release Notes • September 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM includes a distributed architecture which enables you to manage Sun Storage See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS. The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported. Common Array Manager Software Features. The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.1. iSCSI support for Sun StorageTek 2510 Array Minimal (CLI-only) installationFirmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another (6.x to 7.x) requires a utility specific to the array family.The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring..

Popular Topics